800 sq ft attic, uninsulated
Closing the full gap to R-38 with blown-in cellulose
$1,860 to $2,520
Saves about $282/yr · pays back in 7.8 years
Nevada · DOE climate zone 3 · 1.00× national labor
Nevada sits in DOE climate zone 3, which calls for R-38 in the attic and R-13 in exterior walls. Work out your gap, what closing it costs at Nevada rates, and what it saves.
Total estimated cost
$1,940to$2,630
Midpoint $2,286 · range reflects local pricing and site conditions
| Item | Cost |
|---|---|
| Blown-In Cellulose material5.4 in to close an R-19 gap over 1,200 sq ft | $912 |
| Waste allowance10% overage for trimming and irregular framing | $91 |
| Installation laborNevada rate (1.07x national) | $1,283 |
| Estimated total | $2,286 |
Estimated energy savings
$36per year
Pays back in 50+ years
Cooling savings are priced at 13.6¢/kWh, the average residential electricity rate in Nevada, published by the EIA for 2026-05. Uses 2,800 heating and 1,800 cooling degree days for zone 3.
This models heat conduction through the assembly only. It excludes air leakage and duct losses, which in an older house are frequently larger than conduction, so real savings are often higher than this figure, and it is a planning estimate rather than an energy audit.
Same job, other materials
Nevada is predominantly in climate zone 3, the lower south and much of coastal california, warm summers with a real but short winter.
| Building component | Recommended R-value | Priority |
|---|---|---|
| Attic | R-38 | Start here. |
| Exterior walls | R-13 | Second priority in cold zones, rarely first anywhere. |
| Floors | R-19 | Worth doing when the space below is genuinely unconditioned and cannot be sealed instead. |
| Crawl space | R-19 | In humid climates, encapsulating and insulating the crawlspace walls usually beats insulating the floor above it. |
| Basement walls | R-11 | Most valuable in cold zones with conditioned or semi-conditioned basements. |
These are Department of Energy recommendations for existing homes. New construction follows whichever IECC code cycle your jurisdiction has adopted, and California and Washington both set targets above the federal recommendation.
Priced with the Nevada labor multiplier of 1.00× and zone 3 R-value targets applied.
Closing the full gap to R-38 with blown-in cellulose
$1,860 to $2,520
Saves about $282/yr · pays back in 7.8 years
Topping up to the zone 3 recommendation of R-38
$1,940 to $2,630
Saves about $36/yr · pays back in 50+ years
Closed-cell spray foam to R-19, which also seals air and blocks moisture
$4,920 to $6,650
Saves about $322/yr · pays back in 18.0 years
All six materials priced for the same 1,200 sq ft attic going from R-19 to R-38, at Nevada labor rates.
| Material | R / inch | Depth needed | Total cost | Air sealing | DIY? |
|---|---|---|---|---|---|
| Fiberglass Batt | R-3.2 | 5.9 in | $1,817 | None | Yes |
| Blown-In Cellulose | R-3.5 | 5.4 in | $2,286 | Moderate | Yes |
| Blown-In Fiberglass | R-2.5 | 7.6 in | $2,487 | None | Yes |
| Rigid Foam Board | R-5 | 3.8 in | $2,718 | Moderate | Yes |
| Open-Cell Spray Foam | R-3.7 | 5.1 in | $4,974 | Excellent | No |
| Closed-Cell Spray Foam | R-6.5 | 2.9 in | $6,939 | Excellent | No |
Nevada sits predominantly in DOE climate zone 3, warm. That zone determines every R-value target that follows, and it is why a single national insulation recommendation is close to useless.
For zone 3, the Department of Energy recommends R-38 in the attic, R-13 in exterior walls, R-19 in floors over unconditioned space, R-19 in crawl spaces and R-11 in basement walls. Those are recommendations for existing homes; new construction is governed by whichever IECC code cycle your jurisdiction has adopted.
Still cooling-led, but the heating season is long enough to matter. R-38 in the attic is the standard target, with floor and crawlspace work worth doing in humid areas. Several states straddle two zones, and mountainous counties frequently sit a zone colder than the state figure suggests, if you are at altitude, check your county rather than taking the state number.
Bringing a 1,200 square foot Nevada attic from R-19 up to the recommended R-38 costs $1,940 to $2,630 professionally installed with blown-in cellulose, about $1.91 per square foot. That closes an R-19 gap, which needs roughly 5.4 inches of additional material, or 24 bags. Starting from bare joists instead costs $3,289, because the gap is R-38 rather than R-19. The gap sets the bill, not the square footage.
Nevada labor runs exactly at the national average, and insulation is a labor-heavy trade: installation accounts for 40-60% of a professional job. DIY blown-in work brings the same project to about $1,123, since most suppliers lend the blower free with a material purchase.
We estimate that upgrade saves roughly $36 per year on heating and cooling, pricing the cooling half at 13.6¢ per kWh, the average residential electricity rate in Nevada published by the US Energy Information Administration for 2026-05. Cooling-dominated in the south, mixed in Reno; attic R-38 plus duct sealing leads on payback.
That figure models heat conduction through the assembly only. It excludes air leakage and duct losses, which in an older house are frequently larger than conduction, so real-world savings are often higher than this, and the payback shorter. Treat it as a conservative planning figure rather than an energy audit. Note too that returns diminish sharply: this top-up saves $36 a year, while closing the full R-0 to R-38 gap on the same attic saves $422 and pays back in 7.8 years. The first few inches do most of the work.
The attic is where almost every Nevada home should start, and it is the assembly this attic insulation calculator is set up for by default. Zone 3 calls for R-38, which is 10.9 inches of blown-in cellulose over a bare ceiling, 15.2 inches of blown fiberglass, or 11.9 inches of fiberglass batt. Measure what is up there first, depth in inches divided by roughly 3 gives a workable existing R-value.
Two details decide whether the job performs as calculated. Keep the material off the soffit vents, using baffles at the eaves, because blocking that airflow is how a well-insulated attic ends up with a damp roof deck. And if you are laying batts over existing insulation, use unfaced ones, a second vapor barrier partway through the assembly traps moisture between the layers.
The climate here is arid, with extreme summer heat in the south and cold winters in the north. That means the attic runs far hotter than the house below it through the summer, and radiant heat down through the ceiling plane is a real cooling load rather than an afterthought. Depth plus a properly sealed ceiling plane does more about it than any single product upgrade.
For the same Nevada attic top-up, the six materials land a long way apart: $1,817 in fiberglass batt, $2,286 in blown-in cellulose, $2,487 in blown fiberglass and $6,939 in closed-cell spray foam. Batt is cheapest to install and least forgiving of a sloppy fit; run the blown in insulation calculator setting instead and the material flows around wiring, ducts and irregular framing, which is why it dominates retrofits.
Cellulose is the value pick in an open attic at R-3.5 per inch, the best of the affordable materials, and it dense-packs into closed wall cavities without opening the wall. Its one real drawback is settling, roughly 10-20% over the first few years unless it is packed to density, which installers allow for by blowing slightly deep.
Switch to the spray foam insulation calculator setting and the picture changes: at R-6.5 per inch, closed-cell foam reaches the Nevada target in 5.8 inches and seals air leaks in the same operation. It costs $4,653 more than cellulose on this attic, which is money well spent where depth is limited (a shallow crawl space, a vaulted ceiling, a 2x4 wall) and hard to justify on an open attic floor where you can simply add depth.
Exterior walls are the second-largest opportunity in the Nevada envelope, and the hardest to reach. Insulating 1,500 square feet of uninsulated wall to R-13 costs about $2,462 here and saves roughly $441 a year; the wall insulation calculator prices that assembly directly if you switch the area selector.
In zone 3, the honest ranking is: air sealing first, attic second, everything else after that. Sealing bypasses around plumbing stacks, recessed lights and the attic hatch costs a fraction of what insulation does and frequently delivers more comfort improvement per dollar.
Cooling-dominated in the south, mixed in Reno; attic R-38 plus duct sealing leads on payback. That reflects the balance between heating and cooling load here. Zone 3 is cooling-dominated, with roughly 2,800 heating degree days and 1,800 cooling degree days in a typical year.
Before you buy material, check for utility rebates. Many Nevada utilities offer per-square-foot incentives on attic insulation that meaningfully change the payback math, and some cover a free energy audit that will identify air leaks you would not find yourself. On a $2,286 job, a typical rebate is a large enough share to change which material makes sense.
Every figure on this page comes from the same open formula the calculator above uses. We start from your state's DOE climate zone, look up the R-value the Department of Energy recommends for the assembly you are insulating, subtract the R-value already in place, and price only the gap that is left, which is why two houses of identical size get very different numbers. Depth comes from the material's published R per inch, material cost from a 2026 national baseline per square foot per inch, and a 10% allowance is added for trimming and irregular framing. Installed labor is then scaled by the construction earnings multiplier the Bureau of Labor Statistics publishes for your state. The energy saving is a steady-state conduction estimate priced against real US Energy Information Administration residential electricity rates and a national natural gas price, with a 70% realization factor applied. It deliberately excludes air leakage, duct losses and solar gain, so it is a conservative planning figure rather than an energy audit. Nothing is hidden behind a lead form and no contractor pays to appear here. What this is not is a quote: attic access, obstructions, existing damage and any air sealing or venting work are priced separately by whoever does the job.
Nevada sits predominantly in DOE climate zone 3. The lower South and much of coastal California, warm summers with a real but short winter. That single figure sets every R-value target that follows, R-38 in the attic and R-13 in exterior walls here, which is why a national insulation recommendation is close to useless. Several states span two zones, and mountainous counties often sit a zone colder than the state figure; if you are at altitude, check your county specifically.
For zone 3, the Department of Energy recommends R-38 in the attic, R-13 in exterior walls, R-19 in floors over unconditioned space, R-19 in crawl spaces and R-11 in basement walls. In practical depth that is 10.9 inches of blown-in cellulose across the attic floor, or 11.9 inches of fiberglass batt. Those are recommendations for existing homes; new construction in Nevada follows whichever IECC code cycle your jurisdiction has adopted. Our R-value table lists every zone and assembly if you want to compare.
Bringing a 1,200 sq ft attic from R-19 up to the recommended R-38 costs $1,940 to $2,630 installed with blown-in cellulose in Nevada, about $1.91 per square foot. That closes an R-19 gap, which takes roughly 5.4 inches of material. Starting from bare joists instead costs $3,289, because the gap is R-38 rather than R-19. Doing the work yourself brings the top-up to about $1,123.
Insulating a 2,000 sq ft attic from bare joists to the zone 3 target of R-38 costs $4,660 to $6,300 in Nevada with blown-in cellulose, roughly $2.74 per square foot, or about 80 bags of material. Adding the exterior walls of a two-storey house, about 1,500 sq ft insulated with batts, takes the whole-house figure to around $7,289. Labor here runs 1.07× the national average, and it is 40-60% of a professional job, which is the half of the bill that moves when you cross a state line.
Fiberglass Batt is the cheapest professionally installed route in Nevada at about $1.51 per square foot on a 1,200 sq ft attic top-up, which reflects a local labor market at 1.07× the national rate. Blown-in cellulose costs marginally more to install but fills around wiring, ducts and irregular framing far better, which is why it dominates attic retrofits here. Doing it yourself drops it further, blown-in cellulose comes to roughly $1,123 for the same attic, since labor is 40-60% of a professional insulation job and most suppliers lend the blower free with a material purchase. Closed-cell spray foam is the expensive end at $6,939, and it earns that only where depth is limited or air sealing is the actual problem.
We estimate the 1,200 sq ft attic top-up above saves roughly $36 a year on heating and cooling in Nevada, paying back a professional install in about 50+ years. An uninsulated attic is the case worth acting on: closing the full gap to R-38 saves about $422 a year and pays back in 7.8 years. The cooling half is priced at 13.6¢ per kWh, the Nevada residential average published by the US Energy Information Administration for 2026-05. The model covers conduction only and ignores air leakage, so real savings in an older house are usually higher.
Frequently, yes. Many Nevada utilities offer per-square-foot incentives on attic insulation, and some fund a free energy audit that will find air leaks you would not locate on your own. Federal tax credits for qualifying insulation improvements have also been available in recent years. Check your utility's current program before buying material, on a $2,286 attic job, a typical rebate is a large enough share to change which material makes sense.
Usually no. R-values add together, so blowing new insulation straight over existing batts is normal practice and gets you to the target for less money than starting again. Remove the old material only where it is genuinely compromised: water-damaged, mold-affected, rodent-contaminated, or vermiculite, which may contain asbestos and needs testing before anyone disturbs it. One detail matters if you are adding batts rather than blown-in, use unfaced batts, because a second vapor barrier partway through the assembly traps moisture between the layers.
Air seal first, almost always. Sealing bypasses around plumbing stacks, recessed lights, duct penetrations and the attic hatch costs a fraction of what insulation does and frequently delivers more comfort per dollar. Insulation slows conduction; it does very little about air moving through the assembly, and blown-in material laid over an unsealed ceiling plane hides the leaks without fixing them. Zone 3 is cooling-dominated, with roughly 2,800 heating degree days and 1,800 cooling degree days a year, so leaks here cost money in both directions.
The figure beside each state is its construction labor multiplier relative to the national average of 1.00×.
Every figure on this page traces back to a published source. Where a government dataset is available, we fetch it at build time rather than typing in a number and hoping it stays true.
Data last updated: August 17, 2026